Re: [Fwd: Re: Problem with Astra 1200s]

Lee Nevo (lnevo@usa.net)
Sat, 24 Jul 1999 16:11:00 -0400

I apologize for sending the attachments, forgot about the charges that
others occur. I was just being impatient. Won't happen again.

Anyway, back to businees...I disconnected the tape drive internally from
the controller card. I enabled termination on the card. The kernel
reports that termination is active. The kernel also reports that the
card is an Ultra SCSI card, however my documentation does not mention
that. In any event, I converted the length of my SCSI cable from feet to
centimeters, and since its a 4' cable, that should be 121.92 cm, so I
should be under the limit. No luck, same issue.

I guess my next step is to go out and find a better terminator to put on
the scanner?

Thanks again and sorry again...

Lee

Oliver Rauch wrote:
>
> Lee Nevo wrote:
>
> >
> > The tape drive is internal and so its got a pretty short cable. I
> > believe its terminated properly. The scanner has a four foot 50 pin to
> > 25 pin SCSI cable. Very high quality (cost me 37 bucks!). I'm using the
> > terminator that came with the scanner. The previous output from dmesg
> > showed that the SCSI card had termination enabled, although in the BIOS
> > this was set to Auto. I have turned off the termination on the SCSI
> > card, and that didn't make any difference. I can definitely give a shot
> > at checking the termination on the tape drive and even disconnecting it
> > completely if you think it will help, but like I said, the tape drive
> > works just fine, and the scanner works great in Windows.
> >
>
> It does not mean anything if it works fine under windows, linux uses the
> hardware much harder (and faster) then windows does, we often had
> the effect that a scanner worked under windows and it did not under linux.
> After changing a scsi cabnle or the termination everything worked fine!
>
> Please check the termination!
>
> Is your scsi-controller an ultra-scsi-controller?
> If yes, may be your cable is too long, on ultra scsi the cable length of
> all cables has to be shorter than 150 cm.
>
> Please disconnect the internal tape drive (remove cable from controller!!!)
> and activate the termination of the controller and check in the boot message that
> the controller termination is activated!
>
> Please don`t send any unrequested images or core-files,
> I get a lot of such unrequested and often unnecessary files and
> my modem has to work hard to get this files and in germany the
> telephone does cost a lot!
>
> Bye
> Oliver
>
> --
> EMAIL: Oliver.Rauch@Wolfsburg.DE
> WWW: http://www.wolfsburg.de/~rauch

--
Source code, list archive, and docs: http://www.mostang.com/sane/