(no subject)

Hilario Ortigosa Monteoliva (Sonicrave@vnet.es)
Mon, 05 Oct 1998 22:56:32 +0000

Hi i'm new in this mailing list.

I would want to start with anynithing neither a problem, but, well....

I have a "MUSTEK MFC-06000CZ 1.02" installed and correctly detected by My tekram dc-390/u driver and
de aspiroute.sys driver (i'm using the os/2 port of sane). Well, when i try to obtain a preview or to scan, the
scanner only moves the ccd 4 or 5 centimeters and the software returns this error:

(TMP28318.ERR with tebug options set to 128:)

[sanei_init_debug]: Setting debug level of sanei_scsi to 128.
[mustek] scsi_wait_ready: sending TEST_UNIT_READY
[mustek] line_distance: got factor=65535, (r/g/b)=(0/4/8)
[mustek] line_distance: fixed up to factor=65535, (r/g/b)=(0/4/8)
[mustek] get_image_status: bytes_per_line=1004, lines=1334
[mustek] lines_per_buffer=32, bytes_per_line=1004
[sanei_scsi] sanei_scsi_cmd: semaphore failure.
[mustek] reader_process: failed to enqueue read req, status: Error during device I/O
[dll] get_parameters(handle=0x31688,params=0x2827e00)
[dll] read(handle=0x31688,data=0x2827e18,maxlen=32768,lenp=0x2827de4)
[mustek] read 0 bytes
[mustek] do_stop: terminating reader process
[mustek] do_stop: reader process terminated with status 0x900
[mustek] do_stop: sending STOP command
C:\OS2SANE\SCANIMAGE.EXE: stopping scanner...
[dll] cancel(handle=0x31688)
[sanei_scsi] sanei_scsi_cmd: semaphore failure.
[mustek] do_stop: closing scanner
C:\OS2SANE\SCANIMAGE.EXE: sane_read: Error during device I/O
[dll] close(handle=0x31688)
[dll] exiting

Where could be the problem ? :?

/=================================================/
/ Hilario Ortigosa Monteoliva |Sonicrave@vnet.es /
/ | /
/ The SoNiC RaVeR! | 2:345/224.13 /
/=================================================/

--
Source code, list archive, and docs: http://www.mostang.com/sane/
To unsubscribe: echo unsubscribe sane-devel | mail majordomo@mostang.com