Backends included in the current tarball - see SANE Distribution |
|
genesys
|
1.0-8 |
Canon
|
CanoScan LiDE 35 |
USB |
0x04a9/0x2213 |
good
|
Same ids as LiDE 50. |
sane-genesys
|
| CanoScan LiDE 50 |
USB |
0x04a9/0x2213 |
good
|
|
| CanoScan LiDE 60 |
USB |
0x04a9/0x221c |
good
|
|
| CanoScan LiDE 40 |
USB |
0x04a9/0x2213 |
untested
|
Same ids as LiDE 50. Please tell us if this scanner works. |
|
plustek
|
0.52 |
Canon
|
CanoScan N670U/N676U/LiDE20 |
USB |
0x04a9/0x220d |
complete
|
|
sane-plustek
|
| CanoScan N1240U/LiDE30 |
USB |
0x04a9/0x220e |
complete
|
|
| CanoScan LiDE25 |
USB |
0x04a9/0x2220 |
good
|
|
|
unsupported
|
2008-01-18 |
Canon
|
CanoScan LiDE 70 |
USB |
0x04a9/0x2225 |
unsupported
|
Philips chip. Backend started, see link |
|
| CanoScan LiDE 80 |
USB |
0x04a9/0x2214 |
unsupported
|
GL841 based, to be added to genesys backend |
| CanoScan LiDE 90 |
USB |
0x04a9/0x1900 |
unsupported
|
Unsupported. See link for details. |
| CanoScan LiDE 100 |
USB |
0x04a9/0x1904 |
unsupported
|
Actually a GL846, by hardware inspection |
| CanoScan LiDE 200 |
USB |
0x04a9/0x1905 |
unsupported
|
GL843? see Bugs item #311335 |
| CanoScan LiDE 500F |
USB |
0x04a9/0x221f |
unsupported
|
GL841 based, to be added to genesys backend |
| CanoScan LiDE 600 |
USB |
0x04a9/0x2224 |
unsupported
|
Philips chip. Backend started, see link |
| CanoScan LiDE 600F |
USB |
0x04a9/0x2224 |
unsupported
|
Philips chip. Backend started, see link |
| CanoScan LiDE 700F |
USB |
0x04a9/0x221f |
unsupported
|
Actually GL847 based? to be added to genesys backend |
|
Backends included in the development repository - see SANE git Access |
|
genesys
|
1.0-8 |
Canon
|
CanoScan LiDE 100 |
USB |
0x04a9/0x1904 |
complete
|
|
sane-genesys
|
| CanoScan LiDE 200 |
USB |
0x04a9/0x1905 |
complete
|
only 2400 dpi resolution is missing but is being worked on |
| CanoScan LiDE 35 |
USB |
0x04a9/0x2213 |
good
|
Same ids as LiDE 50. |
| CanoScan LiDE 40 |
USB |
0x04a9/0x2213 |
good
|
Same ids as LiDE 50. |
| CanoScan LiDE 50 |
USB |
0x04a9/0x2213 |
good
|
|
| CanoScan LiDE 60 |
USB |
0x04a9/0x221c |
good
|
|
|
plustek
|
0.52 |
Canon
|
CanoScan N670U/N676U/LiDE20 |
USB |
0x04a9/0x220d |
complete
|
|
sane-plustek
|
| CanoScan N1240U/LiDE30 |
USB |
0x04a9/0x220e |
complete
|
|
| CanoScan LiDE25 |
USB |
0x04a9/0x2220 |
good
|
|
|
unsupported
|
2010-06-09 |
Canon
|
CanoScan LiDE 70 |
USB |
0x04a9/0x2225 |
unsupported
|
Philips chip. Backend started, see link |
|
| CanoScan LiDE 80 |
USB |
0x04a9/0x2214 |
unsupported
|
GL841 based, to be added to genesys backend |
| CanoScan LiDE 90 |
USB |
0x04a9/0x1900 |
unsupported
|
Unsupported. See link for details. |
| CanoScan LiDE 100 |
USB |
0x04a9/0x1904 |
unsupported
|
Actually a GL846, by hardware inspection |
| CanoScan LiDE 200 |
USB |
0x04a9/0x1905 |
unsupported
|
GL843? see Bugs item #311335 |
| CanoScan LiDE 500F |
USB |
0x04a9/0x221f |
unsupported
|
GL841 based, to be added to genesys backend |
| CanoScan LiDE 600 |
USB |
0x04a9/0x2224 |
unsupported
|
Philips chip. Backend started, see link |
| CanoScan LiDE 600F |
USB |
0x04a9/0x2224 |
unsupported
|
Philips chip. Backend started, see link |
| CanoScan LiDE 700F |
USB |
0x04a9/0x221f |
unsupported
|
Actually GL847 based? to be added to genesys backend |